Business Type:
Manufacturer/Factory,Trading Company
Establishment:
2012
R&D Capacity:
OEM, ODM, designandmanufacture
Terms of Payment:
LC, T/T, D/P, cash
OEM/ODM Service
Sample Available

Hydro Power, Generator, Power Plant manufacturer / supplier in China, offering Turbine Generator / Hydro Generator / Water Generator, Hydro Power Generator, Small Francis Hydro Turbine/Water Turbine Generator and so on.

1
    YRS
General Supplier
Supplier Homepage Industrial Equipment & Components Power & Generating Sets Hydro Generator China Small Francis Turbine Francis Turbine for Hydro Power Plant

China Small Francis Turbine Francis Turbine for Hydro Power Plant

Get Latest Price
Min. Order / Reference FOB Price
10 Piece Contact Supplier
Local Area: Beijing, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, cash
Output Type: AC Three Phase
Size: Medium
Type: Francis
Small Francis turbine / Francis turbine for hydro power plant
Francis turbine
Francis turbine is a kind of turbine suit to water head 20-300meters and with certain suitable flow.
It could be divided into vertical and horizontal arrangement. Francis turbine have the advantage of high efficiency, small size and reliable structure.
Horizontal Francis turbine unit, with horizontal shaft, could be 2 or three supports. Which is normally one stair arrangement. Simple structure, easier operation and maintainence.
Vertical Francis turbine unit, with vertical shaft, metal spiral case or concrete spiral case. With adjustable guide vane, and stay ring etc parts, are suit to runner diameter bigger than 1000mm. Our engineer will select the most suitable Francis turbine for your hydro power project.
Francis runner
Francis runner material could be stainless steel or carbon steel. The upper crown, lower ring, and blades are partial casted, polished, and then welded together. After heat treatment and fine polished, the factory tests including static and dynamic balance test, UT test, and dimension measurement. Our runners are guaranteed 100% all parameters meet the requirement, and related regulation.
Fuchun Industry Development Co., ltd Shenzhen is an experienced manufacture and engineering Company in small scale hydro power equipment ( 50Kw to 50Mw). We play the role of manufacture and EPC contractor andcould supply water to wire equipments and services.
Fuchun has a experienced and professional team to work for site survey, civil work design and power system design. Also there is a strong after sale service to serve at different projects in the world.
We can provide customers with the complete package, from the design and manufacture of the turbine, generator and control equipment through to installation, commissioning and ongoing repair and maintenance.
1. Water Turbine Generator Unit Design & SUPPLY
2. Hydropower equipment supply
3. Feasibility study of hydropower project
4. Manufacture
5. Installation & Supervision
6. Commissioning and Training service
7. Hydro power plant rehabilitant
8. Hydro power plant spares supply
9. Services
Reference List of Some Export Projects

No.Country and Power Station Exported toTechnical ParametersTypeQtyDate of contract1Latin AmericaRated head:305m
Rated flow:0.385m³/s
Frequency:60Hz
Outgoing line voltage:480VCJA475-W-80/2x6.5
SFW1000-8/118012013.062South AsiaType:HL855a
Runner diameter:1750mm27Mw spare runners 12013.063Europe Rated head:73.8m
Rated flow:0.1325m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-55/1x712013.034EuropeRated head:203m
Rated flow:0.312m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-80/1x8.5
SFW500-8/99012013.055South AsiaRated head:88m
Rated flow:1.41m³/s
Frequency:50Hz
Outgoing line voltage:400VHLA550-WJ-62
SFW1000-6/118012013.056West AfricaRated head:210m
Rated flow:0.423m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-80/1x9.5
SFW700-8/118012013.057
Latin AmericaRated head:925m
Rated flow:0.26m³/s
Frequency:60Hz
Outgoing line voltage:4.16KVCJC601-W-100/1x5
SFW1980-6/143022012.128
Southeast AsiaRated head:4m
Rated flow:10m³/s
Frequency:60Hz
Outgoing line voltage:440VZD-LH-160
SF320-36/215012012.129
Latin AmericaRated head:128m
Rated flow:0.6+0.3m³/s
Frequency:60Hz
Outgoing line voltage:440VCJA475-W-80/2x9
SFW614-12/1180
CJA475-W-80/2x6.5
SFW302-12/99022012.1110EuropeRated head:48.51m
Rated flow:0.351m³/s
Frequency:50Hz
Outgoing line voltage:400VXJA-W-55B/1x8.512012.1111EuropeRated head:47.48m
Rated flow:0.38m³/s
Frequency:50Hz
Outgoing line voltage:400VHL110-WJ-4212012.1112EuropeRated head:25.44m
Rated flow:0.332m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD54-WJ-5012012.1113Europe Rated head:35.19m
Rated flow:0.3m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD54-WJ-5012012.1114Europe Rated head:37.82m
Rated flow:0.291m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD54-WJ-5012012.1115Latin AmericaRated head:60m
Rated flow:1.24m³/s
Frequency:60Hz
Outgoing line voltage:440VHLA575c-WJ-56
SFW600-8/99022012.816EuropeRated head:58.1m
Rated flow:0.169m³/s
Frequency:50Hz
Outgoing line voltage:400VXJA-W-40/1x9
SFW100-8/59012012.0417Latin AmericaRated head:38m
Rated flow:1.64m³/s
Frequency:60Hz
Outgoing line voltage:440VHL220-WJ-50
SFW470-8/99012012.0418EuropeRated head:43m
Rated flow:0.59m³/s
Frequency:50Hz
Outgoing line voltage:400VHL110-WJ-42
HLD54-WJ-4022012.0319South AsiaType:HL855a
Runner diameter:1750mm27Mw spare runners 32011.1120EuropeRated head:134m
Rated flow:0.25m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA475-W-80/2x6.5
SFW250-10/85022011.0621EuropeRated head:228m
Rated flow:0.4m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA475-W-85/1x9.5
SFW715-8/118032011.0522EuropeRated head:61.8m
Rated flow:0.221m³/s
Frequency:50Hz
Outgoing line voltage:400VXJA-W-42/1x10
SFW100-8/59012011.0323Europe Rated head:379.7m
Rated flow:0.685m³/s
Frequency:50Hz
Outgoing line voltage:10.5KVCJA475-W-105/2x7.5
SFW2150-8/173012010.1224Europe Rated head:461.6m
Rated flow:0.786m³/s
Frequency:50Hz
Outgoing line voltage:10.5KVCJA475-W-115/2x8
SFW3000-8/173012010.1225EuropeRated head:29m
Rated flow:3.2m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD41-WJ-42
HLD74-WJ-6022010.1226
Middle AsiaRated head:36m
Rated flow:1.67m³/s
Frequency:50Hz
Outgoing line voltage:400VHL295-LJZ-50
SF500--6/85052010.1227
South AsiaRated head:206m
Rated flow:0.89m³/s
Frequency:50Hz
Outgoing line voltage:6.6kVCJA475-W-100/2x10
SFW1500-10/143022010.0828Southeast AsiaRated head:385m
Rated flow:11.24m³/s
Frequency:50Hz
Outgoing line voltage:13.8kV(37.5Mw)HL69-LJ-205
SF37500-10/360022010.0229
East AsiaRated head:206.8m
Rated flow:0.358m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-80/1x9
SFW570-8/99012010.0430
South AsiaRated head:47.5m
Rated flow:2.62m³/s
Frequency:50Hz
Outgoing line voltage:6.6kVHLA696-WJ-68
SFW1000-8/118032010.0331EuropeRated head:35m
Rated flow:4.25m³/s
Frequency:50HzHLA696-WJ-82
SFW800-12/1430
HLJF2504-WJ-56
SFW400-8/99032010.0132EuropeRated head:265m
Rated flow:0.734m³/s
Frequency:50Hz
Outgoing line voltage:6.3kVCJA475-W-110/2x8.5
SFW1600-10/173022009.0733EuropeRated head:289m
Rated flow:1.775m³/s
Nozzle No.:2
Bucket No.: 20
Runner Outer Diameter: 1600mm
RUNNER DIAMETER: 1300mm4000KW Pelton runner and shaft spares 32009.0634
Southeast AsiaRated head:86.2m
Rated flow:22.5m³/s
Frequency:50Hz
Outgoing line voltage:10.5kV(17Mw) HLA883-LJ-155
SF17000-12/325022008.01