Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Potentiostat, Galvanostat, Electrochemical Workstation, Electrochemical Analyzer, ..
Establishment:
2012
R&D Capacity:
OwnBrand
Terms of Payment:
LC, T/T, D/P, PayPal, WesternUnion
Main Markets:
North America, South America, Europe, Southeast Asia, Middle East, Africa, East Asia(Japan, South Korea), Australia, Domestic
OEM/ODM Service
Sample Available

Galvanostat, Electrochemical Workstation, Corrosion Measurement manufacturer / supplier in China, offering Single Channel Potentiostat Galvanostat for Corrosion Measurement, CS150 Potentiostat Galvanostat Electrochemical Analyzer, 10*10 Array Wire Beam Electrode Potential & Current Mapper and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Analysis Instrument Other Analysis Instruments Single Channel Potentiostat Galvanostat for Corrosion Measurement

Single Channel Potentiostat Galvanostat for Corrosion Measurement

Get Latest Price
Min. Order / Reference FOB Price
1 Set US $3.00/ Set
Local Area: Wuhan, Hubei, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, PayPal, WesternUnion
Customized: Non-Customized
Structure: Desktop
Certification: CE, ISO
CS electrochemical workstation (potentiostat / galvanostat) contains a fast digital function generator, high-speed data acquisition circuitry, a potentiostat and a galvanostat. With high performance in stability and accuracy with advanced hardware and well-functioned software, it is a comprehensive research platform for corrosion, batteries, electrochemical analysis, sensor, life science and environmental chemistry etc.
Applications (1) Reaction mechanism of Electrosynthesis, electrodeposition (electroplating), anodic oxidation, etc.
(2) Electrochemical analysis and sensor;(3) New energy materials (Li-ion battery, solar cell, fuel cell, supercapacitors), advanced functional materials, photoelectronic materials;
(4)Corrosion study of metals in water, concrete and soil etc;
(5) Fast evaluation of corrosion inhibitor, water stabilizer, coating and cathodic protection efficiency.HARDWARE FEATURES
Dual-channel high-speed 16bit/high-accuracy 24bit AD converter;
Built-in frequency response analyzer(FRA), frequency range: 10μHz~1MHz;
High-bandwidth high input impedance amplifier unit
Built-in FPGA DDS digital signals synthesizer
High-power Potentiostat/Galvanostat/ZRA;
Potential control range: ±10V; Compliance voltage: ±21V;
Current control range: ±2A ;
Potential resolution: 10μV; current resolution 1pA.
SOFTWARE FEATURES
CS studio software provides users a versatile smoothing/differential/ integration kit, which can complete the calculation of peak height, peak area and peak potential of CV curves.
CS studio also provides powerful non-linear fitting on Butler-Volmer equation of polarization curve. It can calculate Tafel slope, corrosion current density, limitation current, polarization resistance, corrosion rate. It can also calculate the power spectrum density, noise resistance and noise spectrum resistance based on the electrochemical noise measurements.
CS Studio software can achieve real time saving of the measuring data. The data can be automatically saved even in case of sudden power off.
CS studio kit has a built-in versatile timing policy for combined measurements, which can facilitate the automation of experiments and save time.
Battery analysis: charge & discharge efficiency, capacity, specific capacitance, charge & discharge energy etc.
EIS analysis: Bode, Nyquist, Mott-Schottky plotTECHNICAL ADVANTAGES1. Impedance (EIS)
CS potentiostat applies correlation integral algorithm and dual-channel over-sampling technique, and has strong anti-interference ability. It is suitable for EIS measurements of high-impedance system (>109Ω, such as coating, concrete etc.). It can also be used to obtain Mott-Schottky curve and differential capacitance curve. During test, the software can display real-time open circuit potential(OCP) without entering. EIS of AA6063 Al alloy in Ce3+ containing 3% NaCl solution Polarization curve of Ti-based amorphous alloy & stainless steelin 3%NaCl solution2. Polarization curveIt can complete linear polarization curve and Tafel plot measurements. The user can set the anodic reversal current (passivation film breakdown current) of the cyclic polarization curve to determine material's pitting potential and protection potential and evaluate the its susceptibility to intergranular corrosion. The software employs non-linear fitting to analyze polarization curve, and can make fast evaluation of material's anti-corrosion ability and inhibitors.3. Voltammetry It can do the following electroanalysis methods: Linear Sweep Voltammetry(LSV), Cyclic Voltammetry(CV), Staircase Cyclic Voltammetry(SCV), Square wave voltammetry(SWV), Differential Pulse Voltammetry(DPV), Normal Pulse Voltammetry(NPV), AC voltammetry(ACV), Stripping voltammetry etc. It integrates calculation of peak area, peak current and standard curve analysis.LSV curve: mesoporous carbon material in 0.1M KOH CV curves of PPy supercapacitor in 0.5 mol/L H2SO4
4. Electrochemical NoiseWith high-resistance follower and zero-resistance ammeter, it measures the natural potential/currentfluctuations in corrosion system. It can be used to study pitting corrosion, galvanic corrosion, crevice corrosion, and stress corrosion cracking etc. Through noise spectrum, we can evaluate the inducement, growth and death of metastable pitting and crack. based on calculation of noise resistance and pitting index, it can complete localized corrosion monitoring.Electrochemical noise of low-carbon steel in 0.05mol/L Cl-+0.1mol/L NaHCO3
5. Full floating measurement
CS workstation uses full-floating working electrode. It can be used for autoclave electrochemical measurements, on-line corrosion monitoring of metallic components under the ground (rebar in concrete, etc.)
6. User-defined methods
CS workstation supports user-defined combination measurements. The user can set cyclic timing measurements of an electrochemical method or several methods.
We are able to provide API functions and development examples, which facilitates some users' requirements for secondary development and self-defined measurements.SpecificationsSpecificationsSupport 2-, 3- or 4-electrode systemPotentialcontrolrange: ±10VCurrentcontrolrange: ±2APotentialcontrolaccuracy: 0.1%xfullrange±1mVCurrentcontrolaccuracy: 0.1%xfullrangePotentialresolution: 10μV(>100Hz),3μV(<10Hz)Currentsensitivity:1pARisetime: <1μS(<10mA),<10μS(<2A)Referenceelectrodeinputimpedance:1012Ω||20pFCurrentrange: 2nA~2A, 10 rangesCompliancevoltage: ±21VMaximumcurrentoutput: 2ACVandLSVscanrate: 0.001mV~10,000V/sCAandCCpulsewidth: 0.0001~65,000sCurrentincrementduringscan: 1mA@1A/msPotentialincrementduringscan: 0.076mV@1V/msSWVfrequency: 0.001~100kHzDPVandNPVpulsewidth: 0.0001~1000sADdataacquisition:16bit@1MHz,20bit@1kHzDAResolution:16bit,setuptime:1μsMinimumpotentialincrementinCV: 0.075mVIMPfrequency: 10μHz~1MHzLow-passfilters: Covering8-decadePotentialandcurrentrange: AutomaticPCandO/SrequirementInterface:USB2.0OperatingSystem:Windows2000/NT/XP/ win7/win8/win10Weight / MeasurementsNet weight: 6.5kg Gross weight: 10kgInstrument size: 36.5 x 30.5 x16cm; After package: 52.5 x 37.5x 22.5cmElectrochemicalImpedance Spectroscopy(EIS)SignalgeneratorFrequencyrange:10μHz~1MHzACamplitude:1mV~2500mVDCBias:-10~+10VOutputimpedance:50ΩWaveform: sinewave,triangularwaveandsquare waveWavedistortion:<1%Scanningmode: logarithmic/linear,increase/decreaseSignalanalyzerIntegraltime:minimum:10msorthelongesttimeofacycleMaximum:106cyclesor105sMeasurementdelay:0~105sDCoffsetcompensationPotentialautomaticcompensationrange:-10V~+10VCurrentcompensationrange:-1A~+1ABandwidth:8-decadefrequencyrange, automaticandmanualsettingSoftwareTechniques / electrochemical methodsCS150CS300CS310CS350Open Circuit Potential (OCP)√√√√Potentiostatic (I-T curve)√√√√Galvanostatic√√√√Potentiodynamic(Tafel plot)√√√√Galvanodynamic√√√√Multi-Potential Steps√√√√Multi-Current Steps√√√√Potential Stair-Step (VSTEP)√√√√Galvanic Stair-Step (ISTEP)√√√√Chronopotentiometry (CP)√√√Chronoamperometry (CA)√√√Chronocoulometry (CC)√√√Cyclic Voltammetry (CV)√√√√Linear Sweep Voltammetry (LSV)√√√√Staircase Voltammetry (SCV) #√√Square wave voltammetry (SWV) #√√Differential Pulse Voltammetry (DPV)#√√Normal Pulse Voltammetry (NPV)#√√Differential Normal Pulse Voltammetry (DNPV)#√√ACvoltammetry (ACV) #√√2nd Harmonic A.C.Voltammetry (SHACV)√√Differential Pulse Amperometry (DPA)√Double Differential Pulse Amperometry (DDPA)√Triple Pulse Amperometry (TPA)√Integrated Pulse Amperometric Detection (IPAD)√EIS vs Frequency (IMP)√√EIS vs Time (IMPT)√√EIS vs Potential (IMPE)(Mott-Schottky)√√Electrochemical Potentiokinetic Reactivation(EPR)√√√√Electrochemical Noise(EN)√√√√Zero resistance Ammeter (ZRA)√√√√Battery charge and discharge√√√√Galvanostatic charge and discharge(GCD)√√√√Data Logger√√√√Electrochemical stripping/deposition√√√Bulk electrolysis with Coulometry (BE)√√√√